Zusammenfassung Time of external start button (AMBrc3 and AMBrc4 decoder) is too low
Sequenz 2790
Klassifikation Bug
Priorität High
Status Done
Startdatum 12.11.2019
Fälligkeitsdatum 12.11.2019
Verantwortlich
Version 2.4.6
Aufwand 0
Beschreibung In Groupstart, the first loop pass after the start caused all cars to finish on the timekeeping screen. The same phenomenon occurred again with the same member re-race, so after that, I ended the following race without using the accessory function.

Kommentare

Zeitstempel Wer Kommentar
12.11.2019 09:56:03 Felix Romer The start has been triggered over the external start button which is connected to the decoder. This caused that 2 passings with the transponder number 9992 has been sent from the decoder to RCM, which one:
- started the heat
- set the decoder offset based on the passed time within this message

But the problem was, that this time has twice been devided by 1000 - instead of only once. This cased that the decoder offset was set way too low (1573393780 instead of 1573393780333) what caused again, the the passing have had a negative time.

Change history

Zeitstempel Wer Änderung
12.11.2019 09:52:20 Ticket erstellt
12.11.2019 09:53:06 Felix Romer Feld: Status
Alter Wert: Opened
Neuer Wert: Running
12.11.2019 16:45:21 Felix Romer Feld: Status
Alter Wert: Running
Neuer Wert: Done